Mounting Considerations
Comdial engineers have designed the FX II so that it can be either rack- or wall-mounted. Regardless
of how you mount the cabinet, there are several things to consider during installation:
always choose a secure and dry mounting location that has plenty of ventilation. Be sure that the
temperature range of the location is within 32–122 degrees F (0–50 degrees C) and that the
humidity is less than 90 percent, non-condensing,
locate the equipment within four feet of a proper AC electrical outlet dedicated exclusively to this
equipment. The outlet must be a 115 VAC 15 AMP circuit with a third-wire ground supplied to a
standard electrical outlet (NEMA 5-15R),
locate the equipment within 25 feet of the TELCO/PBX jacks—this is an FCC requirement.A
nominal distance of seven feet is ideal,
use a reliable earth ground—such as the ground bus in the AC power panel.